PRINT SCOPE


National Association of Testing Authorities, Australia

SCOPE OF ACCREDITATION



AusNet Transmission Group Pty Ltd
MONDO LABORATORY
| Accreditation Number: 1297 | Site Number: 21191 |

Address Details:
28 Raglan Road
AUBURN, NSW 2144
AUSTRALIA
Website: www.mondo.com.au
Contact Details:
Ms Martha Phuong Le
+61(02) 97219004


Availability:Services available to external clients



Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.

 

ISO/IEC 17025 (2005)
Manufactured Goods

SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION/RANGE
Evaluation of electrical appliances and devices - PerformanceWater heatersAir temperature; Current; Distribution temperature; Electrical energy consumption; Electrical voltage; Heat loss and heat-up time; Liquid temperature; Mechanical shock; Overflow; Power; Pressure measurement; Strength and dimensions of components; Strength and dimensions of guarding; Surface temperature; Temperature control; Torque; Volumetric flow; Water pressure range; Not applicableTesting in the laboratory; AS 1056, AS/NZS 4692; Testing in the field; AS 3498AS 3498 up to a maximum flow rate of 47 L/min
Evaluation of gas appliances - Performance and safetyFlue cowls; Twin wall metal flues; Flue draft and spillageNot applicableAS 4566; AS 4567
Gas appliance hoses, hose components and hose assembliesAgeing; Bending properties; Ignitability; Pull-out resistance; Resistance to flexing; Resistance to kinking; Resistance to ozone; Static pressure; Not applicableAG 807; AS 1180; AS 1869
Forklifts and industrial enginesGas safetyNot applicableAS 4983
Liquid petroleum gas (LPG) vehicles and componentsGas safetyNot applicableAG 800; AG 801; AG 802; AG 804; AG 805; AS 1425; AS 4983
Connectors; Control valves; Flame safeguards; Ignition devices; Pressure limit devices; Regulators; Shut-off valves; Thermostats; Static pressure; Temperature; Voltage variation assessment; Not applicableAS 4617; AS 4618; AS 4619; AS 4620; AS 4621; AS 4622; AS 4625; AS 4627; AS 4628; AS 4629; AS 4630; AS 4631; AS 4632; BS EN 125; BS EN 161; BS EN 1552; BS EN 1106; ISO 15995
Gas installations and refuelling stationsGas safetyNot applicableAG 504; AG 806; AG 901; AS 5092; AS 5601
Jointing compounds for use in gas appliance applicationsCorrosion resistance; Resistance to drying; Resistance to gas; Resistance to vibration; Resistance to water; Not applicableAS 4623
Commercial gas cooking appliances; Decorative gas log and other fuel effect appliances; Dedicated liquefied petroleum gas appliances (independent hot plates); Direct gas-fired air heaters; Domestic gas cooking appliances; Domestic gas heating appliances; Domestic gas laundry dryers; Domestic gas refrigerators; Domestic outdoor gas barbeques; Gas pool heaters; Gas water heaters; Incinerating toilets; Indirect gas-fired ducted air heaters; LPG portable and mobile appliances; Radiant gas heaters for outdoor and non-residential indoor use; Cabinet temperature - Refrigerators; Carbon monoxide:carbon dioxide ratio; Cooking oil temperature effects; Cycling durability; Drying performance - Laundry dryers; Emission; Energy consumption; Fan performance - Ducted air heaters; Flow rate - Components; Flue gas temperature; Gas consumption; Gas leakage; Heat flux; Heating up time; Heat resistance; Ice making efficiency; Ignition and flame safeguard; Linting; Maintenance rate; Mechanical stability; Mechanical strength; Moisture removal; Oven baking evenness; Radiant efficiency; Rain effects - Outdoor appliance; Resistance to hydrocarbons; Resistance to oxygen; Safety shut down; Slip of unburnt gas - Catalytic heaters; Stratification evaluation; Temperature hazards; Thermal efficiency; Turndown consumption; Visual examination; Vitiation effects; Wind generator evaluation - Outdoor and room sealed appliance; Not applicableAG 404; AG 504; AG 111; AG 112; AS 2568; AS 3498; AS 3814; AS 4551; AS 4552; AS 4553; AS 4554: 2005; AS 4555: 2002; AS 4556; AS 4557; AS 4558; AS 4560: 2004; AS 4563; AS 4565; AS 4566; AS 4643; AS 5262: 2011 excluding Appendix B9; AS 5263.0; AS/NZS 5263.1.1; AS/NZS 5263.1.2; AS/NZS 5263.1.3; AS/NZS 5263.1.4; AS/NZS 5263.1.5; AS/NZS 5263.1.6; AS/NZS 5263.1.7; AS/NZS 5263.1.8; AS/NZS 5263.1.9; AS/NZS 5263.1.10 (formaldehyde determination using stained tube method); AS/NZS 5263.1.12;  BS EN 203-1; BS EN 203-2; BS EN 203-2-1; BS EN 203-2-2; BS EN 203-2-3; BS EN 203-2-4; BS EN 203-2-6; BS EN 203-2-7; BS EN 203-2-8; BS EN 203-2-9; BS EN 203-2-10;
 BS EN 203-2-11; BS EN 203-3; BS EN 484; BS EN 497; BS EN 498; BS EN 521; BS EN 14543

Material performance evaluation of elastomers, plastics and composite productsPipe material and related products; Prepared test specimens; Failure mode ; Tensile properties; Not applicableISO 13953
0.1 to 100 kN
Peel strength; Tear resistance; Not applicableISO 13954, ISO 13956 - Type B

| Accreditation Number: 1297 | Site Number: 21191 | Printed on : 27-Sep-2020

 

--------------------- END OF SCOPE ----------------------